Varenummer: | 103-355 |
Varekode: | E4A072 |
Vægt: | 1.1g |
Strøm, max.: | 10A |
Temperatur, højeste: | 72°C |
Gruppe: E1115
THERMODISC Micro-Thermal Cut-off Fuses
Series: E4A
Axial
Rated Current: 10(8)A
Features |
• For installation on or in the heating device of electric household appliances, transformers and all types of devices • Switches off devices if the premissible operating temperature is exceeded • After activating, the fuse must be replaced • Secured in dust and dirt proof enclosure • Reacts to surrounding temperatures and is conditionally current sensitive during rated loads |
Technical Specifications |
Contact: | NC |
Rated Current | |
VDE, CSA: | 10A |
UL: | 8A |
Rated Voltage: | 250V AC |
Part Nr. | TRated | TH | TMax |
[°C] | [°C] | [°C] | |
E4A072 | 72 | 47 | 100 |
E4A093 | 93 | 68 | 140 |
E4A098 | 98 | 73 | 140 |
E4A104 | 104 | 79 | 150 |
E4A117 | 117 | 92 | 160 |
E4A121 | 121 | 96 | 160 |
E4A128 | 128 | 103 | 210 |
E4A167 | 167 | 142 | 210 |
E4A192 | 192 | 167 | 210 |
E4A216 | 216 | 191 | 375 |
E4A240 | 240 | 200 | 450 |
TRated = Rated Temperature, TH = Continuous Operating Temperature, TMax = Max. Limiting Temperature | |||
Note |
• The self-heating current is to be taken into consideration when using the thermal fuse • Thermal fuses with separate ventilation can lead to higher currents |
Approvals |