| Varenummer: | 103-363 | 
| Varekode: | E4A121 | 
| Vægt: | 1.1g | 


| Strøm, max.: | 10A | 
| Temperatur, højeste: | 121°C | 
  Gruppe: E1115
  THERMODISC Micro-Thermal Cut-off Fuses
  Series: E4A
  Axial
  Rated Current: 10(8)A
| 
        Features | 
    
| 
        • For installation on or in the heating device of electric household appliances, transformers and all types of devices • Switches off devices if the premissible operating temperature is exceeded • After activating, the fuse must be replaced • Secured in dust and dirt proof enclosure • Reacts to surrounding temperatures and is conditionally current sensitive during rated loads  | 
    
| 
         | 
    
| 
        Technical Specifications | 
    
| 
         | 
    |
| Contact: | NC | 
| Rated Current | |
| VDE, CSA: | 10A | 
| UL: | 8A | 
| Rated Voltage: | 250V AC | 
| 
         | 
    |
| Part Nr. | TRated | TH | TMax | 
| [°C] | [°C] | [°C] | |
| E4A072 | 72 | 47 | 100 | 
| E4A093 | 93 | 68 | 140 | 
| E4A098 | 98 | 73 | 140 | 
| E4A104 | 104 | 79 | 150 | 
| E4A117 | 117 | 92 | 160 | 
| E4A121 | 121 | 96 | 160 | 
| E4A128 | 128 | 103 | 210 | 
| E4A167 | 167 | 142 | 210 | 
| E4A192 | 192 | 167 | 210 | 
| E4A216 | 216 | 191 | 375 | 
| E4A240 | 240 | 200 | 450 | 
| TRated = Rated Temperature, TH = Continuous Operating Temperature, TMax = Max. Limiting Temperature | |||
| 
         | 
    |||
| 
        Note | 
    
| 
        • The self-heating current is to be taken into consideration when using the thermal fuse • Thermal fuses with separate ventilation can lead to higher currents  | 
    
| 
         | 
    
| Approvals | 
             
       |