Varenummer: | 114-353 |
Varekode: | 5XP-A |
Vægt: | 500.0g |
Prøveledningssæt, magnetisk holder, batteri og manual medfølger
Specifications |
||
DC Voltage | Ranges |
200 mV, 2 V, 20 V, 200 V, 1000 V |
Accuracy | ±(1.0 % rdg + 1 dgt) | |
Resolution | 100 µV | |
Input Impedance | 10 MΩ | |
Overload Protection |
200 mV: 1000 V dc or 750 V ac rms (3 minutes) All other ranges: 1000 V dc or 750 V ac rms |
|
AC Voltage True RMS (45 Hz To 500 Hz) |
Ranges | 200 mV, 2 V, 20 V, 200 V, 750 V |
Accuracy | ±(1.5 % rdg + 5 dgts) | |
Resolution | 100 µV | |
Input Impedance | 10 MΩ | |
Overload Protection |
200 mV: 1000 V dc or 750 V ac rms (3 minutes) All other ranges: 1000 V dc or 750 V ac rms |
|
DC Current | Ranges | 200 µA, 2 mA, 20 mA, 200 mA |
Accuracy | ±(1.5 % rdg + 1 dgt) | |
Resolution | 0.1 µA | |
Input Protection | 315 mA/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on mA input | |
Burden Voltage | 300 mV max. (1 V max. on 200 mA range) | |
AC Current | Ranges | 200 µA, 2 mA, 20 mA, 200 mA |
Accuracy | ±(2.0 % rdg + 5 dgts) | |
Resolution | 0.1 µA | |
Input Protection | 315 mA/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on mA input | |
Burden Voltage | 300 mV max. (1 V max. on 200 mA range) | |
Resistance | Ranges | 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ, 20MΩ |
Resolution | 100mΩ | |
Accuracy |
200Ω, 2kΩ, 20kΩ, 200kΩ: ±(1.0 % rdg + 4 dgts) 2MΩ: ±(1.5 % rdg + 4 dgts) 20MΩ: ±(2.0 % rdg + 5 dgts) |
|
Open Circuit Voltage | 0.3 V dc typical, (3.0 V dc on 200Ω range) | |
Overload Protection | 1000 V dc or 750 V ac rms | |
Continuity | Audible Indication | 75 ohm±25 ohm |
Response Time | 100 ms | |
Overload Protection | 1000 V dc or 750 V ac rms | |
Diode Test | Test Current | 1.0 mA (approximate) |
Accuracy | ±(1.5 % rdg + 3 dgts) | |
Resolution | 1 mV | |
Open Circuit Voltage | 3.0 V dc typical | |
Overload Protection | 1000 V dc or 750 V ac rms | |
Battery Test | Ranges | 1.5 V, 9 V |
Accuracy |
±(3.5 % rdg + 2 dgts) | |
Resolution | 1 mV, 10 mV | |
Loaded Current | 150 mA typical for 1.5 V range, 5 mA typical for 9 V range | |
Overload Protection |
1000 V dc or 750 V ac rms on 9 V range, on VWinput 315 mA/1000 V fast blow ceramic fuse on 1.5 V range, on mA input |
|
Non-Contact Voltage Indicator | Sense voltage 70 V to 600 V ac; beeper chirps and bright red LED comes on, works on all ranges |