| Varenummer: | 129-448 |
| Varekode: | RCP-2000-24 |
| Vægt: | 2.0kg |


|
Features |
|
• Enclosed case, built-in fan • Universal input • Overload protection, current limiting, auto recovery • Protections: short circuit/over load/over voltage • Built-in active PFC function • Low profile • Parallel function • Active current sharing up to 6000W (3 units) • Built-in remote On/Off control • Built-in remote sense function • AC OK & DC OK signal • Built-in auxiliary power • Hot-swap function • Internal ORing diode |
|
|
|
Technical Specifications |
|
|
|
|
Input Voltage: |
90...264V AC (47...63Hz) |
|
127...370V DC |
|
|
Input Inrush Current, Max.: |
50A |
|
Leakage Current, Max.: |
1,1mA |
|
Output Voltage Adjustment: |
-12/+16% |
|
Over Load Protection: |
105...125% |
|
Withstand Voltage |
|
|
I/P-O/P: |
3000V AC |
|
I/P-FG: |
1500V AC |
|
O/P-FG: |
700V AC |
|
Operating Temperature: |
-40...+70°C |
|
Weight: |
2000g |
|
I/P = Input, O/P = Output, FG = Frame Ground |
|
|
|
|
|
Part Nr. |
UA |
IA |
PA |
DUA |
URN |
h |
|
[V] |
[A] |
[W] |
[%] |
[mVp-p] |
[%] |
|
| RCP-2000-12 |
12 |
0...100 |
1200 |
2 |
150 |
86 |
| RCP-2000-24 |
24 |
0...80 |
1920 |
1 |
200 |
90,5 |
| RCP-2000-48 |
48 |
0...42 |
2016 |
1 |
300 |
92 |
|
UA = Output Voltage, IA = Output Current Range, PA = Output Power, DUA = Output Voltage Tolerance, URN = Ripple & Noise, h = Efficiency |
||||||
|
|
||||||
| Labelling |
![]() |
|
|
| Terms of Delivery |
|
Minimum order quantity: 1 PKU = 1 piece |
|
|
| Manufacturer |
![]() |
| http://www.meanwell.com |
|
|
Control/Monitor Rack f. RCP-2000
Varenummer: 129-450
Varekode: RKP-1UI-CMU1
| Inkl. moms | |
| Kr. 4.500,00 | |
| v/5 | Kr. 4.375,00 |
| v/10 | Kr. 4.125,00 |
Control/Monitor Unit f. RCP-2000
Varenummer: 129-452
Varekode: RKP-CMU1
| Inkl. moms | |
| Kr. 3.000,00 | |
| v/5 | Kr. 2.750,00 |
| v/10 | Kr. 2.500,00 |