Kontaktor 3pol NO, Kontakter, 20 A, 12 V dc spole

Varenummer:141-365
Varekode:LP1K0910JD3
Henter lager-information...
Henter lager-information fra leverandører...
Internet-pris
Inkl. moms
Kr. 593,75

LP1K0910JD3 Kontaktor 3pol NO, Kontakter, 20 A, 12 V dc spoleLP1K0910JD3 Kontaktor 3pol NO, Kontakter, 20 A, 12 V dc spole

Kontaktor med 3 NO, Kontakter, 20 A, 12 V dc spole

Characteristics 

Main
range of product
TeSys K
 
range
TeSys
 
product or component type
Contactor
 
product name
TeSys K
 
device short name
LP1K
 
device application
Control
 
contactor application
Motor control
Resistive load
 
Complementary
utilisation category
AC-3
AC-1
AC-4
 
poles description
3P
 
pole contact composition
3 NO
 
[Ue] rated operational voltage
690 V AC 50/60 Hz for power circuit
<= 690 V AC 50/60 Hz for signalling circuit
 
[Ie] rated operational current
9 A at <= 440 V AC AC-3 for power circuit
20 A (<= 50 °C) at <= 440 V AC AC-1 for power circuit
16 A (<= 70 °C) at 690 V AC AC-1 for power circuit
 
control circuit type
DC standard
 
[Uc] control circuit voltage
12 V DC
 
motor power kW
2.2 kW at 400 V AC 50/60 Hz AC-4
2.2 kW at 220...230 V AC 50/60 Hz AC-3
4 kW at 380...415 V AC 50/60 Hz AC-3
4 kW at 440 V AC 50/60 Hz AC-3
4 kW at 480 V AC 50/60 Hz AC-3
4 kW at 500...600 V AC 50/60 Hz AC-3
4 kW at 660...690 V AC 50/60 Hz AC-3
 
auxiliary contact composition
1 NO
 
[Uimp] rated impulse withstand voltage
8 kV
 
overvoltage category
III
 
[Ith] conventional free air thermal current
20 A at <= 50 °C for power circuit
10 A at <= 50 °C for signalling circuit
 
Irms rated making capacity
110 A AC for power circuit conforming to NF C 63-110
110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
 
rated breaking capacity
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
110 A at 220...230 V conforming to IEC 60947
110 A at 380...400 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
 
[Icw] rated short-time withstand current
20 A <= 50 °C >= 15 min power circuit
90 A <= 50 °C 1 s power circuit
85 A <= 50 °C 5 s power circuit
80 A <= 50 °C 10 s power circuit
60 A <= 50 °C 30 s power circuit
45 A <= 50 °C 1 min power circuit
40 A <= 50 °C 3 min power circuit
80 A 1 s signalling circuit
90 A 500 ms signalling circuit
110 A 100 ms signalling circuit
 
associated fuse rating
25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
 
average impedance
3 mOhm at 50 Hz - Ith 20 A for power circuit
 
[Ui] rated insulation voltage
690 V for signalling circuit conforming to IEC 60947-4-1
690 V for signalling circuit conforming to IEC 60947-5-1
600 V for signalling circuit conforming to UL 508
600 V for power circuit conforming to CSA C22.2 No 14
600 V for signalling circuit conforming to CSA C22.2 No 14
690 V for power circuit conforming to IEC 60947-4-1
600 V for power circuit conforming to UL 508
 
insulation resistance
> 10 MOhm for signalling circuit
 
inrush power in W
3 W at 20 °C
 
hold-in power consumption in W
3 W at 20 °C
 
heat dissipation
3 W
 
control circuit voltage limits
0.8...1.15 Uc at <= 50 °C operational
0.1...0.75 Uc at <= 50 °C drop-out
 
connections - terminals
Screw clamp terminals 1 cable(s) 1.5...4 mm² - cable stiffness: solid
Screw clamp terminals 1 cable(s) 0.75...4 mm² - cable stiffness: flexible - without cable end
Screw clamp terminals 1 cable(s) 0.34...2.5 mm² - cable stiffness: flexible - with cable end
Screw clamp terminals 2 cable(s) 1.5...4 mm² - cable stiffness: solid
Screw clamp terminals 2 cable(s) 0.75...4 mm² - cable stiffness: flexible - without cable end
Screw clamp terminals 2 cable(s) 0.34...1.5 mm² - cable stiffness: flexible - with cable end
 
operating rate
3600 cyc/h
 
coil technology
Built-in bidirectional peak limiting diode suppressor
 
auxiliary contacts type
Type instantaneous (1 NO)
 
minimum switching current
5 mA for signalling circuit
 
minimum switching voltage
17 V for signalling circuit
 
mounting support
Plate
Rail
 
tightening torque
1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2
1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
 
operating time
10 ms coil de-energisation and NO opening
30...40 ms coil energisation and NO closing
 
safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
 
non overlap distance
0.5 mm
 
mechanical durability
10 Mcycles
 
electrical durability
0.18 Mcycles 20 A AC-1 at Ue <= 440 V
1.3 Mcycles 9 A AC-3 at Ue <= 440 V
 
mechanical robustness
Shocks contactor closed, on Z axis 15 Gn for 11 ms IEC 60068-2-27
Shocks contactor opened, on Z axis 10 Gn for 11 ms IEC 60068-2-27
Vibrations contactor closed 4 Gn, 5...300 Hz IEC 60068-2-6
Vibrations contactor opened 2 Gn, 5...300 Hz IEC 60068-2-6
Shocks contactor opened, on X axis 10 Gn for 11 ms IEC 60068-2-27
Shocks contactor opened, on Y axis 6 Gn for 11 ms IEC 60068-2-27
Shocks contactor closed, on X axis 15 Gn for 11 ms IEC 60068-2-27
Shocks contactor closed, on Y axis 10 Gn for 11 ms IEC 60068-2-27
 
height
58 mm
 
width
45 mm
 
depth
57 mm
 
product weight
0.225 kg
 
Environment
standards
BS 5424
IEC 60947
NF C 63-110
VDE 0660
 
product certifications
UL
CSA
 
IP degree of protection
IP2x conforming to VDE 0106
 
protective treatment
TC conforming to IEC 60068
TC conforming to DIN 50016
 
ambient air temperature for operation
-25...50 °C
 
ambient air temperature for storage
-50...80 °C
 
operating altitude
2000 m without derating in temperature
 
flame retardance
V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102