• Enclosed case, screw terminals
• Universal input
• Overload protection, current limiting, auto recovery
• Protections: short circuit/over load/over voltage
• Built-in active PFC function
|
|
|
|
|
Input Voltage:
|
85...264V AC (47...63Hz)
|
120...370V DC
|
Input Inrush Current, Max.:
|
30A
|
Leakage Current, Max.:
|
2mA
|
Output Voltage Adjustment:
|
+10/-5
|
Over Load Protection:
|
105...150%
|
Withstand Voltage
|
I/P-O/P:
|
3000V AC
|
I/P-FG:
|
1500V AC
|
O/P-FG:
|
500V AC
|
Operating Temperature:
|
-10...+60°C
|
Weight:
|
660g
|
I/P = Input, O/P = Output, FG = Frame Ground
|
|
|
|
|
|
|
|
|
Part Nr.
|
UA
|
IA
|
PA
|
DUA
|
URN
|
h
|
|
[V]
|
[A]
|
[W]
|
[%]
|
[mVp-p]
|
[%]
|
SP-100-3,3
|
3,3
|
0...20
|
66
|
2
|
100
|
70
|
SP-100-5
|
5
|
0...20
|
100
|
2
|
100
|
76
|
SP-100-7,5
|
7,5
|
0...13,5
|
101,2
|
2
|
100
|
78
|
SP-100-12
|
12
|
0...8,5
|
102
|
2
|
100
|
80
|
SP-100-13,5
|
13,5
|
0...7,5
|
101,2
|
2
|
100
|
80
|
SP-100-15
|
15
|
0...6,7
|
100,5
|
2
|
100
|
82
|
SP-100-24
|
24
|
0...4,2
|
100,8
|
1
|
150
|
84
|
SP-100-27
|
27
|
0...3,8
|
102,6
|
1
|
150
|
83
|
SP-100-48
|
48
|
0...2,1
|
100,8
|
1
|
250
|
82
|
UA = Output Voltage, IA = Output Current Range, PA = Output Power, DUA = Output Voltage Tolerance, URN = Ripple & Noise, h = Efficiency
|
|
|