Varenummer: | 129-409 |
Varekode: | RSP-2400-12 |
Vægt: | 3.5kg |
Features |
• Enclosed case, built-in fan, screw terminals • Overload protection, current limiting, shut down after 5s • Protections: short circuit/over load/over voltage • Built-in active PFC function • Low no load power consumption • Parallel function • AC input active surge current limiting • Active current sharing up to 4800W (1+1 units) • Built-in remote On/Off control • Power fail signal • Built-in remote sense function • Built-in auxiliary power 12V/0,1A |
Technical Specifications |
Input Voltage: |
180...264V AC (47...63Hz) |
254...370V DC |
|
Input Inrush Current, Max.: |
60A |
Leakage Current, Max.: |
2mA |
Output Voltage Adjustment: |
±10% |
Over Load Protection: |
100...112% |
Withstand Voltage |
|
I/P-O/P: |
3000V AC |
I/P-FG: |
2000V AC |
O/P-FG: |
500V AC |
Operating Temperature: |
-20...+70°C |
Weight: |
3300g |
I/P = Input, O/P = Output, FG = Frame Ground |
|
Part Nr. |
UA |
IA |
PA |
DUA |
URN |
h |
[V] |
[A] |
[W] |
[%] |
[mVp-p] |
[%] |
|
RSP-2400-12 |
12 |
0...166,7 |
2000,4 |
1 |
150 |
87 |
RSP-2400-24 |
24 |
0...100 |
2400 |
1 |
150 |
89,5 |
RSP-2400-48 |
48 |
0...50 |
2400 |
1 |
200 |
91,5 |
UA = Output Voltage, IA = Output Current Range, PA = Output Power, DUA = Output Voltage Tolerance, URN = Ripple & Noise, h = Efficiency |
||||||
Note |
You will find installation material in product group L7617. |
Labelling |
|
Terms of Delivery |
Minimum order quantity: 1 PKU = 1 piece |
Manufacturer |
|
http://www.meanwell.com |