Varenummer: | 88-787 |
Varekode: | V23047-2401 |
Vægt: | 19.6g |
Features |
• Relay with forcibly guided contacts according to EN50205 • Large insulation gap to secure separation of circuit • Category of protection RTIII (wash tight) |
![]() |
Application |
Emergency shut-off, machine control, elevator and escalator control, light barrier control |
![]() |
Technical Specifications |
![]() |
|
Contact |
|
V23047-_01: |
DPDT |
V23047-_11: |
1 NO+1 NC |
Contact Material: |
AgNi |
Rated Current: |
6A |
Max. Switching Voltage: |
400V AC |
Max. Switching Power: |
1500VA |
Creepage/Clearance: |
8/8mm |
Operate/Release Time: |
10/4ms |
Testing Voltage |
|
Coil/Contact: |
4000Vrms |
Contact/Contact: |
3000Vrms |
Opening Contact: |
1500Vrms |
Lifetime |
|
Mechanical: |
10x106 Operations |
Operating Temperature: |
-25...+70°C |
Weight Approx.: |
20g |
![]() |
Coil Data |
Part Nr. |
UN |
UAn |
UAb |
PN |
RN |
[V DC] |
[V] |
[V] |
[mW] |
[W] |
|
V23047-1201 |
12 |
9 |
1,2 |
699 |
206 |
V23047-2401 |
24 |
18 |
2,4 |
700 |
823 |
V23047-2411 |
24 |
18 |
2,4 |
700 |
823 |
UN = Rated Voltage, UAn = Operate Voltage, UAb = Release Voltage, PN = Rated Power, RN = Coil Resistance; All Specifications Measured at 23°C |
|||||
![]() |
Norms |
Forcibly guided contacts according to EN50205. |
![]() |
Approvals |
![]() ![]() ![]() |
![]() |
Terms of Delivery |
Minimum order quantity: 1 PKU = 1 piece |
![]() |
Manufacturer |
TE Connectivity http://www.te.com |
![]() |