Varenummer: | 105-765 |
Varekode: | MPS-200-24 |
Vægt: | 605.0g |
Features |
• Open frame • Contact pin for nylon-crimp terminals • Universal input • Overload protection, pulsing hiccup shutdown, auto recovery • Protections: short circuit/over load/over voltage • Built-in active PFC function • Built-in remote On/Off control • Built-in remote sense function • Power Good/Fail Signal • EN60601-1 compliant • Peak load capability |
Technical Specifications |
Input Voltage: |
90...264V AC (47...440Hz) |
127...370V DC |
|
Input Inrush Current, Max.: |
40A |
Leakage Current, Max.: |
0,18mA |
Output Voltage Adjustment: |
+10/-5% |
Over Load Protection: |
120...160% |
Withstand Voltage |
|
I/P-O/P: |
4000V AC |
I/P-FG: |
1500V AC |
O/P-FG: |
1500V AC |
Operating Temperature: |
-20...+70°C |
Weight: |
660g |
I/P = Input, O/P = Output, FG = Frame Ground |
|
Part Nr. |
UA |
IA |
PA |
DUA |
URN |
h |
[V] |
[A] |
[W] |
[%] |
[mVp-p] |
[%] |
|
MPS-200-3.3 |
3,3 |
0...28 |
92,4 |
2 |
80 |
77 |
MPS-200-5 |
5 |
0...28 |
140 |
2 |
80 |
81 |
MPS-200-12 |
12 |
0...11,7 |
140,4 |
2 |
100 |
84 |
MPS-200-15 |
15 |
0..9,4 |
141 |
2 |
100 |
85 |
MPS-200-24 |
24 |
0...5,9 |
141,6 |
1 |
150 |
86 |
MPS-200-48 |
48 |
0...3 |
144 |
1 |
200 |
87 |
UA = Output Voltage, IA = Output Current Range, PA = Output Power, DUA = Output Voltage Tolerance, URN = Ripple & Noise, h = Efficiency |
||||||
Note |
You will find suitable crimp housings in product group L7611. |
Labelling |
|
Terms of Delivery |
Minimum order quantity: 1 PKU = 1 piece Articles in bold print in stock, other articles of 1 piece upwards available on request, delivery time approx. 14 weeks. |
Manufacturer |
|