Varenummer: | 105-485 |
Varekode: | QP-100-3C |
Vægt: | 920.0g |
Features |
• Enclosed case, screw terminals • Universal input • Overload protection, pulsing hiccup shutdown, auto recovery • Protections: short circuit/over load/over voltage • Built-in active PFC function |
Technical Specifications |
Input Voltage: |
90...264V AC (47...63Hz) |
127...370V DC |
|
Input Inrush Current, Max.: |
40A |
Leakage Current, Max.: |
3,5mA |
Output Voltage Adjustment |
|
CH1: |
+10/-5% |
CH2: |
+10/-5% |
Over Load Protection: |
105...150% |
QP-100B, QP-100C: |
105...135% |
Withstand Voltage |
|
I/P-O/P: |
3000V AC |
I/P-FG: |
1500V AC |
O/P-FG: |
500V AC |
Operating Temperature: |
-10...+60°C |
Weight: |
870g |
QP-100B, QP-100C: |
1100g |
I/P = Input, O/P = Output, FG = Frame Ground |
|
Part Nr. |
UA |
IA |
PA1) |
DUA |
URN |
h |
[V] |
[A] |
[W] |
[%] |
[mVp-p] |
[%] |
|
QP-100-3A |
5 |
2...10 |
99,4 |
3 |
100 |
74 |
3,3 |
0...10 |
3 |
100 |
|||
12 |
0,3...3 |
6 |
150 |
|||
-5 |
0...1 |
5 |
150 |
|||
QP-100-3B |
5 |
2...10 |
100 |
3 |
100 |
74 |
3,3 |
0...10 |
3 |
100 |
|||
12 |
0,3...3 |
6 |
150 |
|||
-12 |
0...1 |
5 |
150 |
|||
QP-100-3C |
5 |
2...10 |
100,9 |
3 |
100 |
75 |
3,3 |
0...10 |
3 |
100 |
|||
15 |
0,3...2 |
+8/-6 |
150 |
|||
-15 |
0...1 |
5 |
150 |
|||
QP-100-3D |
5 |
2...10 |
104,8 |
3 |
100 |
75 |
3,3 |
0...10 |
3 |
100 |
|||
24 |
0,3...2 |
6 |
150 |
|||
-12 |
0...1 |
5 |
150 |
|||
QP-100D |
5 |
2...10 |
100 |
3 |
120 |
78 |
12 |
0...3 |
3 |
150 |
|||
24 |
0,3...2 |
6 |
200 |
|||
-12 |
0...1 |
5 |
150 |
|||
QP-100F |
5 |
2...10 |
103 |
3 |
120 |
78 |
15 |
0...3 |
3 |
180 |
|||
24 |
0,3...2 |
6 |
200 |
|||
-15 |
0...1 |
5 |
150 |
|||
QP-100B |
5 |
2...10 |
101 |
3 |
100 |
76 |
12 |
0,3...4 |
6 |
150 |
|||
-12 |
0,15...1 |
+10/-6 |
150 |
|||
-5 |
0...1 |
5 |
100 |
|||
QP-100C |
5 |
2...10 |
101 |
3 |
100 |
77 |
15 |
0,3...3 |
+6/-10 |
150 |
|||
-15 |
0,15...1 |
8 |
150 |
|||
-5 |
0...1 |
5 |
100 |
|||
UA = Output Voltage, IA = Output Current Range, PA = Output Power, DUA = Output Voltage Tolerance, URN = Ripple & Noise, h = Efficiency, 1) The Sum of the Power Used by the Individual Channels Must Not Exceed the Total Power Rating. |
||||||
Note |
You will find installation material in product group L6911. |
Labelling |
|
Terms of Delivery |
Minimum order quantity: 1 PKU = 1 piece Articles in bold print in stock, other articles of 1 piece upwards available on request, delivery time approx. 14 weeks. |
Manufacturer |
|
http://www.meanwell.com |