| Varenummer: | 101-583 | 
| Varekode: | RCH50K022 | 
| Vægt: | 8.9g | 


| Produkt: | Modstand | 
| Modstand: | 22kΩ | 
| Tolerance: | ±5% | 
| Effekt, max.: | 50W | 
| 
      Features | 
  
| 
      • 50W at 25°C heatsink mounted (optional) • Compact size • Easy mounting • High insulation: 106MW  | 
  
| 
       | 
  
| 
      Technical Specifications | 
  
| 
       | 
  |
| 
      Tolerance: | 
    
      ±5% | 
  
| 
      Power Rating | 
  |
| 
      Without Heatsink: | 
    
      5,5W | 
  
| 
      With Heatsink1): | 
    
      50W | 
  
| 
      Operating Voltage, Max.: | 
    
      1285V | 
  
| 
      Dielectric Strength: | 
    
      3500V | 
  
| 
      Temperature Coefficient | 
  |
| 
      <1W: | 
    
      ±250ppm/°C | 
  
| 
      >1W: | 
    
      ±150ppm/°C | 
  
| 
      Thermal Resistance: | 
    
      0,8°C/W | 
  
| 
      Temperature Range: | 
    
      -55...+125°C | 
  
| 
      Climatic Category: | 
    
      55/125/56 | 
  
| 
      Derating: | 
    
      See Curve | 
  
| 
      1) For calculation of heatsink please see values below Note | 
  |
| 
       | 
  |
| Note | 
| • You will find suitable heatsinks at product group G9511. | 
| 
       | 
  
| 
      Calculation of heatsink | 
  
| 
      P = DT / [RTH(j-c) + RTH(c-a)] P = Expressed in W DT = Difference between maximum working temperature (125°C) and room temperature RTH(j-c) = Thermal resistance of the component RTH(c-a) = Thermal resistance of the heatsink and quality of fastening device Example: Ambient Temperature 30°C, Power Rating: 70W 1) P = DT / [RTH(j-c) + RTH (c-a)] 2) DT = 125°C - 30°C = 95 K 3) [RTH(j-c) + RTH (c-a)] = DT / P = 95K / 70W = 1,36K/W4) RTH (c-a) = 1,36K/W - 1K/W = 0,36K/W  | 
  
| 
       | 
  
| Terms of Delivery | 
| 
      Minimum order quantity: 1 PKU = 2 pieces | 
  
| 
       | 
  
| Manufacturer | 
      Vishay/Sfernice![]()  | 
  
| http://www.vishay.com | 
| 
       |