• UL standard fuse
• Low breaking capacity
• As primary protection in equipment
• Material tube: glass
• Material endcaps: nickel-plated copper alloy
• Climate category 40/085/21 according to IEC 60068-1
|
|
|
|
|
Rated Voltage:
|
250V AC
|
Rated Current:
|
0,063...4A
|
Rated Breaking Capacity:
|
35A
|
Fusing Time Limit 0,063...0,1A
|
1,5xIN, Min.:
|
1h
|
2,1xIN, Max.:
|
30min.
|
2,75xIN, Min.:
|
3s
|
2,75xIN, Max.:
|
100s
|
4,0xIN, Min.:
|
800ms
|
4,0xIN, Max.:
|
20s
|
10,0xIN, Min.:
|
60ms
|
10,0xIN, Max.:
|
1s
|
Fusing Time Limit 0,125...4A
|
1,5xIN, Min.:
|
1h
|
2,1xIN, Max.:
|
30min.
|
2,75xIN, Min.:
|
5s
|
2,75xIN, Max.:
|
200s
|
4,0xIN, Min.:
|
1,5s
|
4,0xIN, Max.:
|
40s
|
10,0xIN, Min.:
|
150ms
|
10,0xIN, Max.:
|
3s
|
Temperature Range:
|
-40...+85°C
|
Weight:
|
1g
|
|
|
|
|
|
|
|
Part Nr.
|
IN
|
UN
|
UAb
|
Power
|
Melting
|
|
|
|
|
Dissipation1)
|
Integral2)
|
|
[A]
|
[V AC]
|
[mV]
|
[mW]
|
[A2s]
|
0034.5031
|
0,063
|
250
|
1000
|
220
|
0,037
|
0034.5032
|
0,08
|
250
|
980
|
270
|
0,032
|
0034.5033
|
0,1
|
250
|
870
|
300
|
0,14
|
0034.5034
|
0,125
|
250
|
500
|
270
|
0,259
|
0034.5035
|
0,16
|
250
|
450
|
300
|
1,0
|
0034.5036
|
0,2
|
250
|
400
|
330
|
1,73
|
0034.5037
|
0,25
|
250
|
330
|
350
|
2,53
|
0034.5038
|
0,315
|
250
|
300
|
360
|
4,17
|
0034.5039
|
0,4
|
250
|
225
|
400
|
5,2
|
0034.5040
|
0,5
|
250
|
250
|
440
|
7,9
|
0034.5041
|
0,63
|
250
|
200
|
470
|
13,7
|
0034.5042
|
0,8
|
250
|
160
|
540
|
19,6
|
0034.5043
|
1,0
|
250
|
150
|
540
|
19,4
|
0034.5044
|
1,25
|
250
|
130
|
570
|
33,3
|
0034.5045
|
1,6
|
250
|
100
|
650
|
87
|
0034.5046
|
2,0
|
250
|
100
|
800
|
124
|
0034.5047
|
2,5
|
250
|
90
|
850
|
258
|
0034.5048
|
3,15
|
250
|
90
|
1000
|
395
|
0034.5049
|
4,0
|
250
|
80
|
1150
|
410
|
IN = Rated Current, UN = Rated Voltage, UAb = Voltage Drop, Typ. at 1xIN, 1) Typ. at 1,5xIN, 2) Typ, at 10xIN
|
|
Norms
|
UL 248-14, CSA22.2 No. 248.14, IEC/UL 62368-1
|
|
Labelling
|
|
|
Approvals
|
|
|